FAQ’s – Field Support

Setting up a new base position – New Base Average (AgGPS442 / AgGPS 542 v4.87 and Newer)

Setting up a new base Position – New Base (Here)  (AgGPS442 / AgGPS 542 v4.70 and Older)

Setting up a new base Position – New Base (Here)  (AgGPS442 / AgGPS 542 v4.87 and Newer)

Q – My Base is not flashing between Trans / Sync?

Q – My base says “Rover” instead of “Base”?

Q – My base is not tracking any Satellites?

Q – My FmX or TMX does not drive my valve?

 

 

 

 

 

 
Setting up a new base position – New Base Average (AgGPS442 / AgGPS 542 v4.87 and Newer)

  • With the base station powered up, press the Enter button 3 times
  • You will see “Base Station Edit Current”
  • Press the Right arrow and “Edit Current” will begin to flash
  • Press the Down arrow and you will see “New Base (Avg)”
  • Press the Enter button one time it a 300 Second Timer will begin
  • *Note if the 300 second time does not start, the base has not yet determined its location, please wait and the timer will start automatically.
  • *Note if you see “Base Position Error” this message is OK it is just telling you the base needs a new position.


 

 
Setting up a new base Position – New Base (Here)  (AgGPS442 / AgGPS 542 v4.70 and Older)

  • With the base station powered up, press the Enter button 3 times
  • You will see “Base Station Edit Current”
  • Press the Right arrow and “Edit Current” will begin to flash
  • Press the Down arrow and you will see “New Base (Here)”
  • Continue to press the Enter button until you have reached the Home Screen. (about 12-15 times)
  • *Note if you see “Base Position Error” this message is OK it is just telling you the base needs a new position.


 

 
Setting up a new base Position – New Base (Here)  (AgGPS442 / AgGPS 542 v4.87 and Newer)

  • With the base station powered up, press the Enter button 3 times
  • You will see “Base Station Edit Current”
  • Press the Right arrow and “Edit Current” will begin to flash
  • Press the Down arrow two times and you will see “New Base (Here)”
  • Continue to press the Enter button until you have reached the Home Screen. (about 12-15 times)
  • *Note if you see “Base Position Error” this message is OK it is just telling you the base needs a new position.


 

 
Q – My Base is not flashing between Trans / Sync?

A – This means that the radio got turned off

  • Press the Enter button until you see “Port Radio / Format None”
  • Press the Down arrow and the N of “None” will highlight
  • Press the Right arrow and “None” will begin to flash
  • Press the Down arrow until you see RTK CMR+
  • Press the Enter button till you are back at the Home Screen, and it should now be flashing between Trans / Sync


 

 
Q – My base says “Rover” instead of “Base”?

A – The base station got changed to a Rover.

  • Press the Enter button 2 times till you see “Mode Rover”
  • Press the Right arrow and “Rover” will begin to flash
  • Press the Down arrow and it will say “Base”
  • Press the Enter button until you see “Port Radio / Format None
  • Press the Down arrow and the N of “None” will highlight
  • Press the Right arrow and “None” will begin to flash
  • Press the Down arrow until you see RTK CMR+
  • Press the Enter button till you are back at the Home Screen, and it should now say Base and be flashing between Trans / Sync


 

 
Q – My base is not tracking any Satellites?

A – This is most likely a connection issue:

  • Check the cable that goes between the White Zephyr Geodetic Antenna and the Yellow 442/542
  • This could be loose cables, or moisture inside a connection
  • or this can also be a sign of a bad cable end, worn, frayed, loose.
  • In a very small percentage it could be a faulty GPS Antenna (<1%)


 

 
Q – My FmX or TMX does not drive my valve?

A – 2 things may be going on:

  • Close the field and go to Settings (Wrench) and click on WM Drain, and click Setup, and go to Valve Setup
  • It should display your Valve Module (VM420, VM410, or VM415)
  • Right below that if it says “No Valve”  then the settings did not get saved, Change to PT or PWM depending on your valve type.
    • Gold Digger – PWM
    • Most Machines more than 5 years old PT
  • If this was the case click OK, and click on Implement, and click Save Config, and click Save.

OR

  • Close the field and go to Settings (Wrench) and click on WM Drain, and click Setup, and go to Valve Setup
  • It should display your Valve Module (VM420, VM410, or VM415)
  • If your Valve Module says N/A, then it is a communication issue
  • Unplug both connectors from your valve module leave them unplugged for 10 seconds
  • Power Down your FmX, and while the FmX is powering up reconnect the connectors to your valve module.
  • Go to the Settings (Wrench), and click WM Drain, and click Setup, and go to Valve Setup
  • Your Valve module should now be displayed and functioning, to prevent this do not start your machine while the FmX is powered up.